top of page
Swiss Synergy AG_Hüftprotesen_Knieprotesen_Baar.png

Gruppo Bioimpianti

Korus System

Logo Bioimpianti-Swiss Synergy

The KORUS System was created with the aim of providing the surgeon with comprehensive and reliable solutions for an increasingly personalized surgical procedure. The system comprises:

  • UNCEMENTED KORUS, in two models with 135° and 125° CCD angles, available with or without collar

  • CEMENTED KORUS also available with DISTAL CENTRALIZER

  • KORUS TITAN

  • KORUS MODULAR, equipped with 14 interchangeable necks

UNCEMENTED KORUS

  • Neck with 135° and 125° CCD angles, mirror finish and refined geometry to increase ROM and decrease the risk of impingement

  • Vertical and horizontal grooves: increase the contact surface and ensure axial and rotational stability

  • Stepped geometry: promotes a better grip, exerts an anti-varus action and provides a support surface for unloading the axial components of the forces

  • The low profile of the lateral shoulder allows for easy insertion and reduced incision;

  • Design with or without collar

  • 12/14 standard morse taper with 5°42’30’ angle;

  • Materials:

    • TI6Al4V titanium alloy with OSPROVIT 100 ± 20µm HA coating

Korus-uncemented1_Swiss Synergy_Hüftprothesen
Korus-uncemented_Collar_Swiss Synergy_Hüftprothesen

UNCEMENTED KORUS WITH COLLAR

  • Neck with 135° and 125° CCD angle, mirror finish and refined geometry to increase ROM and decrease the risk of impingement;

  • The collar increases rotational stability and provides additional axial support;

  • The collar size increases with increasing stem size;

  • Stepped geometry: promotes a better grip, exerts an anti-varus action and provides a support surface for unloading the axial components of the forces;

  • 12/14 standard morse taper with 5°42’30’ angle;

  • Materials:

    • TI6Al4V titanium alloy with OSPROVIT HA coating.

CEMENTED KORUS

  • Neck with 135° and 125° CCD angle, mirror finish and refined geometry to increase ROM and decrease the risk of impingement;

  • Available with or without centralizer;

  • Refined distal end to facilitate stem insertion and reduce stresses acting on the cement mantle;

  • Diaphyseal wedge shape: guarantees excellent rotational stability and facilitates the insertion of the stem, thus reducing the stresses acting on the cement mantle;

  • 12/14 standard morse taper with 5°42’30’ angle;

  • Materials: High-nitrogen stainless steel

  • Finish: mirror finish.

Korus-Bioimpianti Swiss Synergy_Hüftprothesen
Korus_Titan_Swiss Synergy_Hüftprothesen

KORUS TITAN

  • Proximal trapezoidal section: resists axial and torsional stress and facilitates osseointegration

  • Square distal section: provides rotational stability without contact with the cortex

  • Materials:

    • Proximal coating: Titanium Y 367 APS (Plasma Spray);

    • Distal section glass bead

KORUS MODULARE

  • 14 interchangeable necks to meet the individual needs of the patient;

  • Two lengths of modular necks;

  • Standard version, varus-valgus 8° or 15°, anteverse/retroverse 8°or 14 and four combined models;

  • Reduced neck geometry;

  • Materials

    • Ti6Al4V titanium alloy with OSPROVIT HA coating;

    • Necks in Cobalt Chrome Alloy.

Korus_Modulare_Swiss Synergy_Hüftprothesen

Hinweis: Bitte lesen Sie vor der Verwendung des Systems die Gebrauchsanweisung sowie OP-Technik für etwaige Vorsichtsmaßnahmen, Indikationen und Kontraindikationen, sowie eventuell auftretende Nebenwirkungen.

bottom of page